CINI MANUAL INSULATION FOR INDUSTRIES PDF

Documents Similar To CINI Manual. Industrial Insulation Manual. Uploaded by. Haris Prawoto. Standard Specification for Hot Insulation (Piping & Equipment). This SPECIFICATION is based on the CINI Handbook “Insulation for Industries”, English. Version, dated 1st October (also known as the ” edition”). This section is based on the Committee Insulation Netherlands. Industry (CINI) Manual “Insulation for Industries”. DACE fol- lows the CINI standard as much as.

Author: Gardabar Faegor
Country: Italy
Language: English (Spanish)
Genre: Relationship
Published (Last): 18 February 2004
Pages: 406
PDF File Size: 6.87 Mb
ePub File Size: 1.95 Mb
ISBN: 200-2-77712-670-6
Downloads: 14711
Price: Free* [*Free Regsitration Required]
Uploader: Yozshuzilkree

Our expert More information. For inspection an ITP Inspection Test Plan shall be submitted, which indicates all phases for test and inspections of the insulation systems.

Air-Conditioning, Heating, and Refrigeration Institute. Technical and industrial insulation. Selecting TEMA Type Heat Exchangers TEMA is a set of standards developed by leading heat exchanger manufacturers that defines the heat exchanger style and the machining and assembly tolerances to be employed.

Extent of mechanical insulation required by this section is indicated on drawings and schedules, and by requirements of this section.

Also acoustic insulation is included. To use this website, you must agree to our Privacy Policyincluding cookie policy. Spacers shall be accurately distanced in order to limit and define the necessary injection volumes.

The protection shall be restricted to a distance of not more than mm horizontally from access walkways and normal working areas. The report shall be subject to the approval of the Principal.

These specifications may be used in whole or in part by any party without. The responsibility of the engineer is. Improper selection and installation account for. Where multi-layering is necessary, longitudinal and circumferential joints shall all be staggered. Pleasants Company James M. The systems and materials shall perform as well as or better than the preferred system and material. The use of proprietary designed mattress jackets, provided with quick release toggles, may be considered.

  COM DATA2 CIRCS 8TH 013595P PDF

Valves and flanges in piping shall be provided with removable insulation covers. Tests shall be carried out in accordance with the applicable test methods. The information set forth in these publications is provided to users for their consideration and decision to implement. The potential cost and safety implications are enormous, and therefore insulation systems shall be designed according to categories that indicate vulnerability to CUI and are related to the process temperatures.

The mass of removable parts shall be less than 25 kg. The factory-assembled support shall have a bonded extended multiplex vapour barrier with a sufficient overlap of 50 mm covered with a bonded 1. Payout time calculations are not recommended.

CINI Manual USB stick

Stilling Well Recommendations White Paper June 24, Stilling Well Recommendations This document describes general requirements for stilling wells used for radar tank gauging applications.

For flammable products, insulation collars of Cellular Glass shall be applied near flanges in order to prevent product from entering the insulation system. Section includes, but is not limited industris, design and furnishing portable davits, davit sleeves, dvit bases, four 4 removable outriggers, More information.

The placing of the pre-formed spacers will depend on the location of supports, welds, auxiliaries, etc. For higher ambient temperatures a calculation shall be carried out to determine the minimum thickness required to achieve a surface temperature of 70 C maximum.

In many More information. VDIor other standards if specified by the Principal, shall be used to calculate the contribution of convection.

The adhesives shall withstand any stresses and strains, accommodate contraction within the foam and remain effective within the required temperature range. Valves, flanges and nozzles shall be insulated, unless other requirements are overruling, e. Circumferential joints between segments in adjacent lengths of pre-formed rigid insulation shall also be staggered.

If required, metal screens or fencing alone shall be designed and provided.

  KUNDALINI YOGA BY SWAMI SIVANANDA RADHA PDF

CINI Manual – Insulation for Industries – Putra Standards

The jacketing shall provide protection against water and weather, fire if requiredoil spillage, mechanical wear or other damage. In general this ror that aluminised steel or stainless steel jacketing shall be applied. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

The heat gain heat ingress for piping in off-plot areas shall be determined by the Principal. Pipe and Equipment Insulations. The Principal may sometimes undertake all or part of the duties of the Main Contractor. Spacers shall be fastened securely by means of stainless steel bands, filament tape or glue. Life cycle costs calculations shall be carried out to arrive to the lowest cost, based on the service life of 20 years.

All work specified in this Section is subject to the provisions of Section These couplings are furnished with restraint rings that, when affixed. LNG loading lines Injection Application methods a and b The foam injection process shall be in accordance with the recommendations of the Manufacturer. Due to practical selection mxnual, the user is able to quickly select the appropriate insulation materials as well as the correct finishing material.

Pipes laid in the ground must be introduced into concrete walls or shafts.

Embedded Parts Introduction – Anchors In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are industriez into contact and built on each other.